総合価格表No42
1149/1636

 各種ブレーカ・その他 手元開閉器(屋内用) ·····································ESB・NSB ……1198手元開閉器(屋外用) ································ESBO・NSBO ……1200切替開閉器 ·····························································KSS ……1202カバースイッチ ·································CS・CKP・CS-DT ……1204ノントリップスイッチ ···································NSL・NSR ……1206中性端子 ····································································NT ……1206中性銅バー ························································ドーバー ……1206銅爪つきヒューズ ······················································C-F ……1206オプションパーツ………………………………………………………1207裏面端子・埋込形端子…………………………………………………1208 資料オプション対応表………………………………………………………1209使用上の注意……………………………………………………………1211参考資料…………………………………………………………………1212外形寸法図………………………………………………………………1214動作特性曲線……………………………………………………………1227 ノーヒューズブレーカ ブレードブレーカ(enステーション分岐回路用)  ··························································NAS・NAS-NT ……1154スマートサイズ(ホーム分電盤分岐回路用) ····NCS-S・NCS-F ……1155スマートサイズ(分岐回路用) ·····················NCB・NCB-S ……1156SBサイズ(分岐回路用) ·················SE-S・SS-B・SE-H ……1157ハーフサイズ(分岐回路用) ·································NLH-M ……1158協約寸法形 ·····························································NL-R ……1159JIS協約形モジュール······································NL-E・NL ……1160経済形 ························································NB-E・NX-E ……1161汎用形 ···································································NX-S ……1162NB型 ················································NB・NX-E・NB-E ……1163分電盤主幹用(単3専用) ················N□-TL・N□-TLA ……1168漏電警報付 ················································NRZ・NEBZ ……1172自家用発電連系側 ············NAS-TLS・NAS-S・NL-TLS ……1174 漏電ブレーカ ブレードブレーカ(enステーション分岐回路用) ·········ZAS ……1176スマートサイズ(ホーム分電盤分岐回路用) ···········ZCS-F ……1177スマートサイズ(分岐回路用) ··································ZCS ……1177SBサイズ(分岐回路用) ············································ZS ……1178ハーフサイズ(分岐回路用) ··································ZLH-M ……1179JIS協約形 ·································································ZL ……1180ZS型 ········································································ZS ……1182ZR型 ········································································ZR ……1184ホーム分電盤主幹用(単3専用) ·························Z□-TL ……1187JIS協約形(単3専用) ·······································ZL-TLA ……1189ZS型(単3専用) ·············································ZS-TLA ……1189ZR型(単3専用) ·············································ZR-TLA ……1190自家用発電連系側 ··········ZLG-TL-S・ZH-TL-S・ZL-TL-S ……1192JIS互換性形 ··················································ZSG・AB ……1194地絡保護専用(OCなし) ···················ZN・AN・AN-TLA ……1195インバーター対応 ·····················································ZL-I ……1196過電圧保護機能付 ··············································AB-GHK ……1196 モータブレーカ モータ保護用漏電ブレーカ ·······································ZML ……1197モータブレーカ ·················································ML・MB ……1197モータブレーカ(箱入り) ········································MBC ……1197使用上の注意施工上の注意●漏電遮断器は、行きの電流と帰りの電流との差が規定以上になった時に動作する仕組みとなっております。よって相の異なる2ヶ所の充電部に触った場合、漏電検出しません。2ヶ所の裸充電部には絶対に触らないようにしてください。●端子部に触らないでください。感電のおそれがあります。●電気機器のアース端子は必ず接地してください。●自動的に遮断した場合は、原因を取り除いてからハンドルを入(ON)にしてください。感電、火災のおそれがあります。●月に一回程度テストボタンを押して動作確認を行ってください。漏電遮断器が切(OFF)にならない場合は故障です。電気工事店へ連絡してください。●保守・点検は専門知識を有する人が上位遮断器を切(OFF)にし、電気がきていないことを確認して行ってください。感電のおそれがあります。●電気工事は、有資格者(電気工事士)が行ってください。●配線作業は、上位遮断器を切(OFF)にし、電気がきていないことを確認して行ってください。感電のおそれがあります。●単相3線式専用の機種は、中性線を必ず中性相に接続してください。欠相又は過電流で動作せずに火災の原因となります。●本体の定格にあった電源に接続してください。不動作及び故障の原因となります。●欠相リード線は負荷側の中性線に確実に締付けてください。接続しないと中性線欠相の検出ができません。●電線接続の際、端子ねじは、適性なトルクで締付けてください。火災のおそれがあります。●高温、多湿、じんあい、腐食性ガス、振動衝撃などの異常環境に設置しないでください。感電、火災、動作しないおそれがあります。●ゴミ、コンクリート粉、鉄粉等の異物及び雨水等が機器内部に入らないように施工してください。火災、動作しないおそれがあります。ブレーカ・開閉器安全に対するご注意  危 険  注 意  注 意

元のページ  ../index.html#1149

このブックを見る